Bedrock SM90
Class 1 Analyzer for PAGA and Speech Intelligibility
Full-featured Class 1 sound analyzer with STIPA and full STI (IEC 60268-16 rev. 4 and rev. 5) for PAGA system testing and compliance. Octave analysis, logging, and environmental monitoring included. Pair with the BTB115 Advanced Talkbox for complete Class 1 speech intelligibility testing.
About this product
The Bedrock SM90 combines Class 1 precision SPL measurement with full STIPA and full STI capability (IEC 60268-16 rev. 4 and rev. 5)—the ideal choice for professional PAGA system testing and formal compliance certification.
Class 1 PAGA Testing Solution
For critical installations requiring formal certification, the SM90 + BTB115 Advanced Talkbox provides Class 1 speech intelligibility testing: - IEC 61672-1 Class 1 SPL measurement - IEC 60268-16 compliant STIPA - All modules active from day one - No unlock fees or subscriptions
Complete Capability
The SM90 ships with octave and 1/3 octave analysis, statistical measurements (L1-L99), data logging, environmental monitoring (temperature/humidity), and STIPA—all active and ready. Data is stored on 8 GB of internal storage (at least 7.8 GB for data), and the battery lasts approx. 4 to 6 hours on a single charge, depending on use, recharging from a USB wall charger. Designed and manufactured in the Netherlands, by the inventors of STIPA.
Professional Compliance Testing
When formal certification is required, the SM90 delivers measurements you can document with confidence. Class 1 compliance according to IEC 61672 and ANSI S1.4.
Pair with the BTB115 Advanced Talkbox
The BTB115 supplies the STIPA test signal for PAGA testing, including large venues, high ambient noise and industrial facilities.
Specifications
| Standards Compliance | IEC 61672-1:2014 Group X Class 1, ANSI S1.4 Type 1, IEC 60268-16 rev. 4 (2011) and rev. 5 (2020), IEC 61260:2014 (RTA filters exceed class 1), ISO 3382-2, ANSI S12.2, ISO 1996 |
| Speech Intelligibility | STIPA and Full STI (IEC 60268-16 rev. 4 (2011) and rev. 5 (2020)) |
| Speech Level Meter | IEC 60268-16 |
| Microphone | BAMT1-MP201, 48 V phantom powered, 1/2" omnidirectional free-field, detachable IEC 61094-4 Type WS rear-vented capsule, alloy housing, nickel diaphragm, Class 1 / Type 1, 16 pF, 50 mV/Pa; works with any 48 V XLR measuring microphone |
| Microphone Dynamic Range | > 146 dB (3% distortion limit) |
| Microphone Coefficients | Temperature -0.012 dB/°C; pressure at 250 Hz -0.004 dB/kPa |
| Effective Noise Floor | < 25 dB(A) (Class 1 device) |
| Linear Range (Z-weighted) | 26-118 dB SPL (low range); 42-124 dB SPL (reference/high range) |
| Linear Measuring Range | 30 - 122 dB with the included microphone; electronics > 110 dB (combined ranges) |
| Environmental Sensors | Temperature and humidity |
| Platform | Shared SMxx hardware platform (SM50, SM90); designed and manufactured in the Netherlands, by the inventors of STIPA |
| Sound Pressure Level | A, C, Z weighting; Slow, Fast, Impulse; Leq, SEL, Max Hold, peak |
| Statistical Acoustics | Percentile levels (L10, L90 and others) |
| Octave Analysis | Real-time analyzer - 1/1, 1/3, 1/6 and 1/12 octave, filters exceed class 1 (IEC 61260:2014), base 10 |
| Logging | LAEQ long-term monitoring and RTA logging |
| FFT Analyzer | FFT analyzer for acoustic and electric input signals |
| Reverberation Time | RT60 (ISO 3382-2) - impulse-response and interrupted-noise methods |
| Noise Curves | NR, NC, PNC, NCB, RC and RC Mark II |
| Building Acoustics | Sound insulation Dn / R' and DnT; SRI / STC; impact sound insulation L'nT and L'nw / L'nTw (firmware 3.2) |
| Electro-Acoustics | Oscilloscope, loudspeaker polarity test, electric RTA and FFT |
| Electric Analysis | AC voltmeter (Vrms, dBU, dBV), fundamental frequency estimation, THD+N |
| Audio Recording | Calibrated audio recording |
| THD+N Measurement | Supported |
| Maximum Permissible SPL | 155 dB (maximum electric input 30 Vpp) |
| Upper Limit Peak Range | 124 dB (highest range, 20 Hz - 20 kHz) |
| Display | 3.2" resistive LCD touch screen, full colour, 320 x 240 pixels, 65k colours, luminance typ. 250 Cd/m2 |
| Data Storage | 8 GB internal storage (at least 7.8 GB for data); accessible from a PC over USB (mass storage mode) |
| Connectivity | USB - data download, remote control, USB audio device mode; remote-control API available for third-party applications |
| Battery | NiMH pack, 4.8 V nominal, typ. 2500 mAh; approx. 4 to 6 hours on a single charge, depending on use; recharging via USB wall charger (international adapters included); max. charge current 1.8 A |
| Start-Up Period | Ready for measurements 20 seconds after power-up |
| Operating Conditions | Temperature 5 - 35 °C (41 - 95 °F); relative humidity 0 - 95% non-condensing |
| EMC | EN 61326-1:2006; FCC part 15 class A |
| Mechanical | Rear-mounted tripod adapter; hook for carrying cord |
| Dimensions | Approx. 210 x 85 x 55 mm (excluding microphone) |
| Weight | 530 g (including microphone) |
| Firmware | Free firmware updates add functionality |
Applications
Explore detailed guides for each application area
Class 1 precision PAGA system testing
Voice alarm certification and compliance testing
Speech intelligibility testing methodology
Regulatory compliance and community noise assessment
Sound insulation, room acoustics, and reverberation
Noise compliance testing and verification
What's Included
Complete kit includes: Rugged hardcase, windscreen, universal power adapter (international plugs), USB cable, calibration certificate, lanyard, a plethora of Excel calculation and reporting sheets, plus Bedrock Studio software. ISO17025 accredited calibration available as an option.
From measurement to report — Bedrock Elite Analyzer
Turn your SM90 measurements into standards-anchored results and branded reports, on your Windows desktop.
- No serial needed to start — run every module in demo mode.
- Branded, standards-referenced PDF reports.
- No add-ons, no per-module fees.
Complete Your Setup with the BAC3 Class 1 Calibrator
For Class 1 instruments like the SM90, we recommend pairing with a Class 1 acoustic calibrator. Regular field calibration ensures your measurements remain traceable and compliant with IEC standards.
- Class 1 to IEC 60942
- 94 dB and 114 dB reference levels
- ISO17025 accredited calibration available
- Compatible with 1/2" and 1" microphones


Extend Your Reach with Outdoor Monitoring
The BOMK00 outdoor kit transforms your measurement capabilities for sustained, unattended noise monitoring. Perfect for environmental assessments, construction site monitoring, and regulatory compliance surveys.
Week-Long Battery
Up to 7 days off-grid operation
Weatherproof Design
Rain, dust, and impact resistant
Remote Access
Bluetooth and WiFi connectivity
Solar Compatible
Extended deployment with solar panels
Frequently Asked Questions
Common questions about the SM90